How a Heat Pump Heats and Cools Your Home

One system, both seasons — here's the physics in plain English.

Reviewed by the Green Comfort Systems team — MD HVAC Master License #78268 Updated 2026-07-07 · 5 min read

What is a heat pump?

A heat pump is an air conditioner that can run in reverse. Instead of burning fuel to create heat, it moves existing heat from one place to another using a refrigeration cycle — out of your house in summer, into your house in winter. Because moving heat takes far less energy than making it, a modern heat pump delivers 2–4 units of heat for every 1 unit of electricity it consumes.

How does it pull heat out of cold winter air?

Even 20°F air contains usable heat energy. The refrigerant inside the outdoor coil boils at extremely low temperatures, so it can absorb heat from air that feels freezing to you. A compressor then squeezes that refrigerant, concentrating the heat to a temperature high enough to warm your home. Cold-climate models we install in the Baltimore metro maintain full heating output well below 5°F.

When is a heat pump the right fit?

  • Your home is all-electric, or you want off natural gas or oil.
  • You're replacing an AC anyway — a heat pump costs modestly more and replaces the furnace's work for most of the winter.
  • You want one system to maintain instead of two.
  • You're claiming the federal 25C tax credit or Maryland utility rebates, which favor high-efficiency heat pumps.

Where do heat pumps go wrong?

Nearly every "my heat pump doesn't work" call we run in Rosedale and Baltimore County traces back to one of three failure modes: an undersized system selected without a load calculation, backup electric heat strips running constantly because the balance point was set wrong, or a standard-efficiency unit installed where a cold-climate model was needed. All three are installer errors, not technology problems.

What we see in the field

Since 2016 our install teams have replaced hundreds of Baltimore-area gas furnaces and AC pairs with cold-climate heat pumps. On properly sized systems, customers typically report winter comfort equal to or better than their old furnace — with steadier temperatures, because heat pumps run longer, gentler cycles instead of blasting on and off.

The refrigeration cycle, in four steps

Every heat pump runs the same loop, and knowing it makes the failure modes obvious. One: refrigerant enters the outdoor coil as a cold, low-pressure liquid and absorbs heat from outside air — even at 20°F, because the refrigerant is colder still. Two: the compressor squeezes that vapour, and pressure raises its temperature well above indoor air. Three: the hot vapour passes through the indoor coil, gives up its heat to the air moving across it, and condenses back to liquid. Four: an expansion device drops the pressure, the liquid goes cold again, and the loop repeats.

In cooling season a reversing valve flips the direction, and the same hardware moves heat the other way. That is the whole trick: a heat pump is an air conditioner that can run backwards, which is why one machine covers both seasons.

What "cold-climate" actually changed

Older heat pumps used single-speed compressors. They ran flat out or not at all, and as outdoor temperature fell, capacity fell with it — right when the house needed more. Below roughly 35°F many older units could no longer keep up, and electric resistance strips picked up the difference at roughly three times the operating cost.

Cold-climate models use variable-speed (inverter-driven) compressors that modulate rather than cycle, along with improved refrigerant control and better defrost logic. The practical result is that a properly selected cold-climate unit holds useful capacity far below the point where older equipment gave up. In the Baltimore metro, where design temperatures are moderate by national standards, that covers the overwhelming majority of hours in a normal winter.

Auxiliary heat and the balance point

The balance point is the outdoor temperature at which your heat pump's output exactly matches the house's heat loss. Above it, the heat pump carries the load alone. Below it, something has to make up the difference — usually electric strips, sometimes a gas furnace in a dual-fuel setup.

Balance point is a property of the pairing, not the equipment: the same heat pump in a well-sealed house has a much lower balance point than in a leaky one. This is also the single most common configuration error we correct. Thermostats often ship with an aggressive default that brings on auxiliary heat far earlier than necessary, and the homeowner sees a winter electric bill that gets blamed on the heat pump rather than the setting.

Why defrost is normal, not a fault

When the outdoor coil runs below freezing, moisture in the air condenses on it and turns to frost. Frost insulates the coil and blocks airflow, so the unit periodically reverses briefly to melt it off. During defrost you may see steam rising from the outdoor unit, hear the reversing valve change position, and notice the supply air cool for a few minutes.

All of that is designed behaviour. What is not normal is defrosting constantly, building visible ice that never clears, or a unit encased in ice at the base — those usually point to a drainage problem, a failed defrost sensor, or low refrigerant charge, and they are worth a service call rather than a wait-and-see.

What a heat pump asks of the rest of the house

A heat pump delivers a larger volume of cooler supply air than a furnace does. Air off a furnace register might be 120–140°F; off a heat pump it is closer to 90–105°F. That is still well above body temperature, but it feels different, and it means the duct system has to move more air to deliver the same heat.

Ducts sized for a furnace are frequently undersized for that airflow, which is why a heat pump retrofit that ignores distribution often disappoints. Before we convert a home, we measure static pressure and look at the return path. In practice, the duct work is more often the deciding factor than the equipment selection.

Common questions we get on the first visit

"Will it feel as warm as my furnace?" The house will hold the same temperature; the air coming out of the register will feel cooler to your hand. Most people stop noticing within a week, but it is worth knowing in advance rather than being surprised on the first cold morning.

"Do I have to give up my gas furnace?" No. A dual-fuel setup keeps the furnace for the coldest hours and runs the heat pump for everything else. If your furnace is healthy and your AC is failing, that is frequently the best-value path.

"Is the outdoor unit noisy in winter?" Modern variable-speed units are quiet at the low speeds they spend most of their time in. You will hear the defrost cycle occasionally. Placement relative to bedroom windows is worth discussing before installation, not after.

"What maintenance does it need?" More than a furnace, because it runs year-round rather than one season. Both a heating and a cooling check, plus outdoor coil cleaning — more often near the water, where salt-influenced air is hard on coils.

Next steps

Ready to compare a heat pump against sticking with gas? Read our heat pump vs. gas furnace comparison for Maryland homes, check what you'd pay in our Baltimore installation cost guide, then see how to claim Maryland rebates and the federal tax credit. Or explore our heat pump installation services directly.